dc.descriptionLa presente investigación tiene como objetivo conocer el comportamiento estructural del Edificio del Laboratorio Clínico Ochoa-Matriz ubicado en la Av. González Suarez del Cantón Ambato en la provincia de Tungurahua. Este trabajo experimental cumple con los requerimientos establecidos en las normas NEC SE CG, NEC SE DS y NEC SE RE, de lo cual se realizó un levantamiento de información arquitectónica y estructural para realizar un modelo matemático en un software especializado de cálculo. Por medio de este programa se determinó los movimientos traslacionales y rotacionales, las derivas, el periodo de diseño, el comportamiento de los elementos estructurales tales como vigas y columnas, además, con la ayuda del programa de cálculo se aplicó la evaluación del desempeño sísmico en la edificación en base a la normativa ASCE/SEI 41-13 para determinar los niveles de desempeño ante solicitaciones de un sismo frecuente, ocasional, raro y muy raro. Así también se analizaron las rótulas plásticas con el objetivo de conocer el desplazamiento y cortante de éstas para categorizar su nivel de desempeño. En base al cálculo establecido en el programa, se estableció que la estructura necesita un reforzamiento para mejorar su capacidad en las columnas, ya que se presentó la falta de esta para soportar las cargas solicitadas en el cálculo y por ello fue necesario utilizar un reforzamiento de revestimiento de hormigón para mejorar su comportamiento estructural.es_ES
dc.description.abstractThis research aims to know the structural behavior of the Ochoa-Matriz Clinical Laboratory Building located on Av. Gonzales Suarez of the Ambato Canton in the province of Tungurahua. This experimental work complies with the requirements established in the NEC SE CG, NEC SE DS and NEC SE RE standards, from which a survey was carried out of architectural and structural information to perform a mathematical model in a specialized calculation software. Through this program it was determined translational and rotational movements, drifts, design period, behaviour of structural elements such as beams and columns, In addition, with the help of the calculation program, the evaluation of seismic performance in the building was applied based based on ASCE/SEI 41-13 to determine the levels of performance before requests of a frequent, occasional, rare and very rare earthquake. Thus, the plastic ball joints were also analyzed to know the displacement and cutting of these to categorize their level of performance. Based In the calculation and therefore it was necessary to use a concrete cladding reinforcement to improve its structural behavior.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectCOMPORTAMIENTO ESTRUCTURALes_ES
dc.subjectLEVANTAMIENTO DE INFORMACIÓNes_ES
dc.subjectMODELO MATEMÁTICOes_ES
dc.subjectEVALUACIÓN DEL DESEMPEÑOes_ES
dc.subjectNIVELES DE DESEMPEÑOes_ES
dc.subjectRÓTULAS PLÁSTICASes_ES
dc.subjectREFORZAMIENTOes_ES
dc.titleAnálisis del desempeño sísmico del edificio de laboratorio Clínico Ochoa - Matrizes_ES