Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/34096
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSuquillo Ronquillo, Betzabeth Jessenia-
dc.contributor.authorTovar Molina, Santiago Alejandro-
dc.date.accessioned2022-01-29T01:55:26Z-
dc.date.available2022-01-29T01:55:26Z-
dc.date.issued2022-01-
dc.identifier.urihttps://repositorio.uta.edu.ec/jspui/handle/123456789/34096-
dc.descriptionEl presente trabajo de investigación se enfocó en implementar varios métodos para la determinación de vulnerabilidad de la estructura perteneciente al Honorable Consejo Universitario de la Universidad Técnica de Ambato, una de ellas es la inspección visual rápida, la cual es un método cualitativo que emplea formatos basados en el FEMA 154, como también normas locales como la Guía 5 de Evaluación y Rehabilitación de estructuras presentada por la NEC 2015. Mediante la implementación de estos métodos se determinó que la estructura en estudio tiene una alta vulnerabilidad. Con la finalidad de verificar los resultados de vulnerabilidad cualitativa obtenidos por los métodos de inspección visual, se utilizó metodologías cuantitativas, para ello se realizó un análisis lineal y no lineal (Pushover). El análisis lineal demostró que la estructura en su estado actual, no cumple con parámetros como el periodo de vibración, la participación torsional y derivas inelásticas, las mismas que se encuentran fundamentadas en la NEC 2015. Por otra parte, mediante el análisis estático no lineal realizado a la estructura en su estado actual, se identificó que esta no posee la capacidad necesaria para poder cumplir con los criterios y niveles de aceptación para las diferentes demandas sísmicas, demostrando que tiene un alto grado de vulnerabilidad. Es por tal motivo que se propuso un reforzamiento con ayuda de la implementación de rigidizadores y un reforzamiento mediante el relleno de hormigón en columnas, para aumentar la capacidad de resistencia, tomando en cuenta que tiene perfiles tubulares cuadrados conformados en frío.es_ES
dc.description.abstractThe present research work focused on implementing several methods for the determination of vulnerability of the structure belonging to the Honorable University Council of the Technical University of Ambato, one of them is the rapid visual inspection, which is a qualitative method that uses formats based in FEMA 154, as well as local regulations such as Guide 5 for the Evaluation and Rehabilitation of structures presented by the NEC 2015. Through the implementation of these methods, it was determined that the structure under study has a high vulnerability. In order to verify the qualitative vulnerability results obtained by visual inspection methods, quantitative methodologies were used, for this a linear and non-linear analysis (Pushover) was performed. The linear analysis showed that the structure in its current state does not comply with parameters such as the period of vibration, torsional participation and inelastic drifts, which are based on the NEC 2015. On the other hand, through the non-linear static analysis carried out on the structure in its current state, it was identified that it does not have the necessary capacity to be able to meet the criteria and acceptance levels for the different seismic demands, showing that it has a high degree vulnerability. It is for this reason that a reinforcement was proposed with the help of the implementation of stiffeners and a reinforcement through the filling of concrete in columns, to increase the resistance capacity, taking into account that it has cold-formed square tubular profiles.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectANÁLISIS ESTRUCTURALes_ES
dc.subjectDESEMPEÑO SÍSMICOes_ES
dc.subjectVULNERABILIDAD SÍSMICAes_ES
dc.subjectPUSHOVERes_ES
dc.subjectMEDICIÓN DE VIBRACIONESes_ES
dc.titleAnálisis estructural del desempeño sísmico del edificio del honorable consejo universitario mediante la medición de vibracioneses_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis I.C. 1545 - Tovar Molina Santiago Alejandro.pdfTESIS A TEXTO COMPLETO5,77 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.