dc.descriptionPara el presente trabajo investigativo se procedió a realizar un análisis comparativo del comportamiento estructural para dos tipos de sistemas que son: el convencional y con la aplicación de un sistema moderno de disipación sísmica, en un edificio de 11 pisos compuesto por dos ascensores en un área de 400 metros cuadrados; La estructura está ubicada en la ciudad de Ambato y se clasificó en especial utilizando la Norma Ecuatoriana de la Construcción. Se utilizó la metodología de un análisis estático no lineal Pushover, para evaluar el desempeño de cada sistema estructural propuesto en base a un sismo de carácter raro que por lo general es el sismo de diseño con un período de retorno de 475 años con una probabilidad de excedencia del 10 por ciento en 50 años. Para el diseño de los elementos estructurales del edificio, así como también para el sistema de disipación sísmica, se utilizaron normas nacionales e internacionales como la Norma Ecuatoriana de la Construcción (NEC 2015), American Society Of Civil Engineers (ASCE 7-16, ACSE 41-13), American Institute Of Steel Constructions (AISC 341-16). Dándonos como resultados los desplazamientos, derivas de piso, energía del sistema, comportamiento y niveles de desempeño de los dos tipos de estructuras con la ayuda del software ETABS 2016.es_ES
dc.description.abstractFor this research work we proceeded to perform a comparative analysis of the structural behavior for two types of systems: conventional and with the application of a modern system of seismic dissipation, in an 11-story building consisting of two elevators in an area of 400 square meters; The structure is located in the city of Ambato and was classified in special using the Ecuadorian Construction Standard. The methodology of a Pushover nonlinear static analysis was used to evaluate the performance of each proposed structural system based on a rare earthquake, which is usually the design earthquake with a return period of 475 years with a 10 percent probability of exceedance in 50 years. For the design of the structural elements of the building, as well as for the seismic dissipation system, national and international standards such as the Ecuadorian Construction Standard (NEC 2015), American Society Of Civil Engineers (ASCE 7-16, ACSE 41-13), American Institute Of Steel Constructions (AISC 341-16) were used. Giving us as results the displacements, floor drifts, system energy, behavior and performance levels of the two types of structures with the help of ETABS 2016 software.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectPUSHOVERes_ES
dc.subjectAISC 341-16es_ES
dc.subjectDISIPADORES SÍSMICOSes_ES
dc.subjectASCE 7-16es_ES
dc.subjectASCE 41-13es_ES
dc.subjectNEC 2015es_ES
dc.subjectBRBes_ES
dc.subjectDESEMPEÑO ESTRUCTURALes_ES
dc.subjectPLACAS GUSSETes_ES
dc.titleAnálisis comparativo del desempeño sísmico en edificos de hormigón de mediana altura aplicando riostras de pandeo restringido en la ciudad de Ambatoes_ES
dc.typebachelorThesises_ES