dc.descriptionEl trabajo de investigación se centró en el estudio del coficiente de convección de un condensador de una instalación frigorfica. Se redujo el sobrecalentamiento del gas de entrada al condensador mediante la reinyección de líquido, para lo cual se realizó un aná- lisis con un modelo matemático y uno experimental con toma de datos de la bancada de refrigeración del laboratorio de energías de la Carrera de Ingeniería Mecánica. Se realizó un modelo matemático para predecir el funcionamiento del sistema frigorfico, y determinar si existe una mejora en el coeficiente de convección del condensador al reinyectar líquido a la entrada del mismo. Estos datos fueron comparados con los datos experimentales. La bancada de refrigeración fue repotenciada y adecuada para la toma de datos, mediante sensores de presión, temperatura y caudalímetros ubicados en puntos fundamentales en el circuito de refrigeración. Se obtuvo una base de datos para analizarlos y comparar los resultados con el modelo matemático predictivo. Una vez analizados los resultados, se obtuvo una reducción no representativa en el coeficiente de convección en el condensador.es_ES
dc.description.abstractThe research work focuses on the study of the convection coficient of the condenser in a refrigeration cycle. The superheating of the incoming gas to the condenser was reduced by the reinjection of liquid. An analysis was carried out by means of a mathematical model and an experimental one with data from the cooling testing bench of the energy laboratory of the Mechanical Engineering Career. A mathematical model was used to predict the operation of the refrigeration system, to determine if there is an improvement in the convection coeficient of the condenser when liquid is injected at the inlet of the condenser. These data were compared with the experimental data. The cooling bench was re-powered and equiped for data collection, using pressure sensors, temperature and flow meters located at fundamental points in the cooling circuit. A database was obtained to analyze and compare the results with the predictive mathematical model. Once the results were analyzed, a non-representative reduction in the convection coeficient in the condenser was obtained.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánicaes_ES
dc.rightsopenAccesses_ES
dc.subjectSUBENRIAMIENTOes_ES
dc.subjectINSTALACIONES FRIGORÍFICASes_ES
dc.subjectREINYECCIÓN DE LÍQUIDOes_ES
dc.subjectSISTEMAS DE REFRIGERACIÓNes_ES
dc.subjectTUBO VENTURIes_ES
dc.subjectDIMENSIONAMIENTO DEL MOTORes_ES
dc.subjectESTUDIO TERMODINÁMICOes_ES
dc.titleMejora del coeficiente de convección en condensadores de instalaciones frigoríficas mediante el subenriamiento del gas de entrada por reinyección de líquidoes_ES