dc.descriptionEl diseño del alcantarillado sanitario tiene el propósito de mejorar la calidad y las condiciones de vida de los habitantes de la comunidad de San Vicente la Independencia, puesto que un sistema de alcantarillado sanitario se considera un servicio básico en todos los sectores poblacionales del mundo. Para el diseño del presente estudio se empleó los equipos; RTK y Drone que permitió la obtención de un levantamiento fotogramétrico de alta precisión, mejorando la calidad y exactitud del estudio; obteniéndose alrededor de 4.000 puntos generados con sus respectivas orientaciones. Durante el diseño del sistema de alcantarillado sanitario se aplicó normativas nacionales e internacionales que respaldan el correcto funcionamiento del presente proyecto técnico. En el proceso del diseño del alcantarillado sanitario, se define que la red cumple con una longitud de 3.759 metros distribuida en la comunidad de San Vicente la Independencia, y a su vez se presenta una propuesta de Planta de Tratamiento para la ampliación del tramo diseñado. En cuanto a la Planta de Tratamiento de Aguas Residuales de la Comunidad de San Vicente la Independencia se realizó la evaluación del afluente y el efluente, brindando datos que relacionan al funcionamiento adecuando de la infraestructura en estudio.es_ES
dc.description.abstractThe purpose of the sanitary sewerage design is to improve the quality of life and living conditions of the inhabitants of the community of San Vicente la Independencia, since a sanitary sewerage system is considered a basic service in all population sectors of the world. For the design of this study, RTK and Drone equipment was used to obtain a highprecision photogrammetric survey, improving the quality and accuracy of the study, obtaining about 4,000 points generated with their respective orientations. During the design of the sanitary sewer system, national and international regulations were applied to support the correct operation of this technical project. In the design process of the sanitary sewerage system, it is defined that the network has a length of 3,759 meters distributed in the community of San Vicente la Independencia, and at the same time a proposal for a Treatment Plant is presented for the expansion of the designed section. Regarding the Wastewater Treatment Plant of the Community of San Vicente la Independencia, an evaluation of the influent and effluent was carried out, providing data that relate to the adequate operation of the infrastructure under study.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectALCANTARILLADO SANITARIOes_ES
dc.subjectCAUDALES DE DISEÑOes_ES
dc.subjectCOEFICIENTES DE MAYORACIÓNes_ES
dc.subjectHIDRÁULICA DE CONDUCTOSes_ES
dc.subjectGRADIENTE HIDRÁULICAes_ES
dc.subjectEFICIENCIA DE REMOCIÓNes_ES
dc.subjectPOBLACIÓN FUTURAes_ES
dc.titleDiseño de un tramo de ampliación del sistema de alcantarillado sanitario y evaluación de la planta de tratamiento de aguas residuales, para mejorar la calidad de vida de la comunidad San Vicente, parroquia La Matriz, cantón Quero, provincia Tungurahuaes_ES