Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/36473
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGuevara Robalino, Jorge Javier-
dc.contributor.authorToro Silva, Valeria Patricia-
dc.date.accessioned2022-09-30T00:29:48Z-
dc.date.available2022-09-30T00:29:48Z-
dc.date.issued2022-09-
dc.identifier.urihttps://repositorio.uta.edu.ec/jspui/handle/123456789/36473-
dc.descriptionCon el propósito de conocer si actualmente trabaja de manera correcta la planta de tratamiento de aguas residuales (PTAR) de la parroquia Quisapincha o con el paso de los años se ha reducido su eficacia en la remoción de contaminantes, se procedió a realizar un levantamiento de información en donde se midió las unidades del tren de tratamiento, el aforo volumétrico en los tanques de entrada y salida de la planta, el análisis de los parámetros físicos-químicos en laboratorio y el diagnostico técnico de cada proceso. Se evaluó el funcionamiento de los procesos unitarios de la planta, los cuales son: Cribado, Sedimentador y tanque repartidos de caudales, filtro biológico de lechuguines, filtro anaeróbico de flujo ascendente y tanque de secado de lodos, demostrando que trabajan de manera correcta en comparación con guías y manuales para el diseño de plantas de tratamientos; y el afluente de salida cumple con la norma TULSMA para descargas en cuerpos de agua dulce. Analizada la información, se concluyó que no es necesario implementar nuevos procesos dentro de la PTAR, sin embargo se propuso recomendaciones para que el sistema funcione de mejor manera.es_ES
dc.description.abstractIn order to determine whether the wastewater treatment plant (WWTP) of the Quisapincha parish is currently working properly or whether its efficiency in the removal of pollutants has been reduced over the years, a survey of information was carried out to measure the units of the treatment train, the volumetric capacity of the plant's inlet and outlet tanks, the analysis of physical-chemical parameters in the laboratory and the technical diagnosis of each process. The operation of the plant's unit processes was evaluated, which are: Screening, sedimentation and flow sharing tank, biological filter of “lechuguines”, upflow anaerobic filter and sludge drying tank, demonstrating that they work correctly in comparison with guides and manuals for the design of treatment plants; and the outflow affluent complies with the TULSMA standard for discharges into freshwater bodies. After analyzing the information, it was concluded that it is not necessary to implement new processes within the WWTP; however, recommendations were proposed for the system to work better.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectPLANTA DE TRATAMIENTOes_ES
dc.subjectAGUA RESIDUALes_ES
dc.subjectTULSMAes_ES
dc.subjectDBOes_ES
dc.subjectDQOes_ES
dc.subjectFAFAVes_ES
dc.titleEvaluación de la planta de tratamiento de aguas residuales de la parroquia Quisapincha, cantón Ambato, provincia de Tungurahuaes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis I.C. 1652 - Toro Silva Valeria Patricia.pdfTESIS A TEXTO COMPLETO6,27 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.