dc.descriptionUna de las metodologías utilizadas es la inspección y evaluación visual rápida por medio de formatos y matrices de la Norma Internacional FEMA 154, y los propuestos por la Normativa Ecuatoriana NEC 2015, con el objetivo de realizar el reconocimiento y clasificar a la estructura por su vulnerabilidad sísmica, con las dos propuestas se determinó el grado de vulnerabilidad medio, para el análisis los parámetros más relevantes fueron: las irregularidades en planta y elevación, el sistema estructural y el tipo de suelo. Con toda la información recopilada se realizó el análisis lineal y el análisis estático no lineal para verificar los parámetros modales, el comportamiento de la edificación y de cada elemento estructural. Con los resultados obtenidos del análisis lineal se determinó que el periodo de vibración y las derivas de piso no cumplen con lo establecido en la Normativa Ecuatoriana, además presenta un comportamiento torsional en sus modos de vibración y del análisis estático no lineal se observó que la edificación tiene deficiente capacidad para los diferentes niveles de amenazas sísmicas presentando un alto grado de vulnerabilidad. Con los resultados de las dos metodologías empleadas se realizó una propuesta de reforzamientos de la edificación, se planteó una a nivel global con la colocación de muros de corte y otra a nivel local con el encamisado de acero para las vigas, mejorando considerablemente su comportamiento y cumpliendo con los chequeos establecidos en las normativas vigentes. Finalmente, se realizó una comparación de los periodos obtenidos por los diferentes análisis con el periodo de vibración obtenido por formulas empíricas que se basaron en vibraciones ambientales, para relacionarlos con el grado de vulnerabilidad de la estructura.es_ES
dc.description.abstractOne of the methodologies used is the rapid visual inspection and evaluation through formats and matrices of the International Standard FEMA 154, and those proposed by the Ecuadorian Regulation NEC 2015, with the objective of recognizing and classifying the structure by its vulnerability seismic, with the two proposals the average degree of vulnerability was determined, for the analysis the most relevant parameters were: irregularities in plan and elevation, the structural system and the type of soil. With all the information collected, the linear analysis and the non-linear static analysis were carried out to verify the modal parameters, the behavior of the building and of each structural element. With the results obtained from the linear analysis, it was determined that the vibration period and the floor drifts do not comply with what is established in the Ecuadorian Regulations, it also presents a torsional behavior in its vibration modes and from the non-linear static analysis it was observed that the building it has a deficient capacity for different levels of seismic threats, presenting a high degree of vulnerability. With the results of the two methodologies used, a proposal to reinforce the building was made, one was proposed at a global level with the placement of shear walls and another at a local level with the steel cladding for the beams, considerably improving their behavior and complying with the checks established in the regulations in force. Finally, a comparison was made of the periods obtained by the different analyzes with the period of vibration obtained by empirical formulas that were based on environmental vibrations, to relate them to the degree of vulnerability of the structure.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectANÁLISIS ESTRUCTURALes_ES
dc.subjectMEDICIÓN DE VIBRACIONESes_ES
dc.subjectDESEMPEÑO SÍSMICOes_ES
dc.subjectESTUDIO DE MATERIALESes_ES
dc.subjectCARGAS GRAVITACIONALESes_ES
dc.subjectCARGA SÍSMICAes_ES
dc.subjectENSAYO DE PENETRACIÓN ESTÁNDARes_ES
dc.titleAnálisis estructural del desempeño sísmico del edificio de Ingeniería Mecánica de la Facultad de Ingeniería Civil y Mecánica mediante la medición de vibracioneses_ES