Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/19365
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBrito Moncayo, Geovanni Danilo-
dc.contributor.authorNúñez Espinoza, Juan Javier-
dc.date.accessioned2016-02-03T20:47:01Z-
dc.date.available2016-02-03T20:47:01Z-
dc.date.issued2016-01-
dc.identifier.othert1101ec-
dc.identifier.urihttp://repositorio.uta.edu.ec/jspui/handle/123456789/19365-
dc.descriptionLínea de investigación: Sistemas electrónicoses_ES
dc.description.abstractRESUMEN En la presente investigación se indica el desarrollo de un sistema encaminado a mejorar el monitoreo del nivel de combustible en la Gasolinera de Milagro. El diseño y funcionamiento del sistema de Monitoreo del nivel de combustible ofrece una medida en tiempo real de una manera más exacta, disminuyendo así posibles accidentes y llevando un control más efectivo al utilizar alarmas preventivas, además de la posibilidad de conectar actuadores con el fin de utilizarlos en tares específicas ya sea apagando bombas de sección o cortando el suministro de combustible. La metodología del diseño está centrada en la de una gasolinera con monitoreo manual que desee la implementación de un sistema automático de medición, presentando un sistema con características fáciles de utilizar y amigables para la persona encargada de monitorear el nivel de combustible, cabe destacar que es una tecnología no invasiva, es decir no tenemos contacto con el combustible como lo hacen otras tecnologías de medición al utilizar ya sea sondas capacitivas o detectores ultrasónicos. Una vez obtenido los datos por el programa se lo almacena en una base de datos MySql para consultas posteriores así como para poder interactuar con otros programas que necesiten la información almacenada. ABSTRACT In this research the development of a system to improve monitoring of the fuel level in the gas station Milagro indicated. The design and operation of fuel level monitoring provides real-time measurement more accurately, thus reducing possible accidents and taking more effective to use preventive alarms control, plus the ability to connect actuators to tary specific use in either turning off pump section or cutting the fuel supply. The design methodology is centered on a gas station with manual monitoring that want to implement an automatic measuring system, introducing a system features easy to use and friendly to the person responsible for monitoring the fuel level, it notes that is a non-invasive technology, ie have no contact with fuel like other measurement technologies using either capacitive probes or ultrasonic detectors. Once the data obtained by the program it is stored in a MySql database for later and to interact with other programs that need the information stored queries.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera de Ingeniería en Electrónica y Comunicacioneses_ES
dc.rightsopenAccesses_ES
dc.subjectMICROCONTROLADORES PICes_ES
dc.subjectMONITOREO DE COMBUSTIBLESes_ES
dc.subjectCONTROL AUTOMÁTICOes_ES
dc.subjectSISTEMAS ELECTRÓNICOS DE MEDICIÓNes_ES
dc.titleMonitoreo del nivel de combustible en la Gasolinera Milagro, utilizando tratamiento digital de imágenes y generación de alarmases_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Tesis Ingeniería Electrónica y Comunicaciones

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis_t1101ec.pdf3,8 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.